imported>Thundercoot |
imported>Denton |
Line 178: |
Line 178: |
| {{Collapsible | | {{Collapsible |
| |Control panel options: | | |Control panel options: |
− | |'''Activate Atmospheric Alarm''': Self Explanatory. The Alarm will show on the Atmos Alert Computers and alerts the AI.
| + | |'''Activate Atmosphere Alarm''': The alarm will show on atmospheric alert computers and alerts silicons. |
| | | |
− | '''Scrubbers Control''': Controls the scrubbers in the area. Select specific gases to be filtered. Choose between two settings for the scrubbers, scrubbing and syphoning.
| |
− | * Scrubbing will slowly drain any gases set to filter in the air of the tile they are on, and transfer it to their pipe. Really, really slow with N2O.
| |
− | * Syphoning will do the same, except indiscriminately and drain all gases on their tile.
| |
| | | |
− | '''Vents Control''': you control vents through the air alarm. There are the following settings: | + | '''Panic Siphon''': Disables all vents in the area and quickly drains all gases. |
− | * '''''External on''', Internal off'': will drain/add air from the tile the vent is on to make it reach the selected pressure. All air being moved goes into/comes out of the pipe the vent is attached to. Set to 0 to drain air, or pressurise to specific levels. | + | |
| + | |
| + | '''Vent Controls''': Changes the settings of vents in the area: |
| + | * '''''External on''', Internal off'': will drain/add air from the tile the vent is on to make it reach the selected pressure. All air being moved goes into/comes out of the pipe the vent is attached to. Set to 0 to drain air, or pressurise to specific levels.<br> Useful for precise pressure control, like room air. |
| + | * ''External off, '''Internal on''''': Drains/adds air to the tile to get the pipe attached to the selected pressure level. Setting a vent to internal and the desired pressure to 0 causes ALL gas which enters the pipe to be shunted out onto the tile.<br> Used for when you want to move gas quickly, like in the Supermatter chamber. |
| *'''''Both on''''': completely useless. Don't bother. | | *'''''Both on''''': completely useless. Don't bother. |
− | * ''External off, '''Internal on''''': Drains/adds air to the tile to get the pipe attached to the selected pressure level. Setting a vent to internal and the desired pressure to 0 causes ALL gas which enters the pipe to be shunted out onto the tile.
| |
| | | |
− | '''Set Environmentals Mode''': you can select a preset mode for the scrubbers and vents in the area:
| |
− | * '''''Filtering''''': Default mode, scrubbers are set to "Filter", vents are set to keep the area at normal pressure (101kPa).
| |
− | * '''''Draught''''': scrubbers are set to "Syphon" and vents are On.
| |
− | * '''''Panic''''': scrubbers are set to "Panic Syphon" and vents are Off.
| |
− | * '''''Replace air''''': scrubbers are set to "Syphon" and vents are Off. Nearly identical to "Panic".
| |
− | * '''''Off''''': Both scrubbers and vents are Off.
| |
| | | |
− | '''Sensor Settings''': Let's you change the minima and maxima for pressure, temperature and specific gases to automatically activate the alarm. | + | '''Scrubber Controls''': Controls the scrubbers in the area. Select specific gases to be filtered. Choose between two settings for the scrubbers, scrubbing and syphoning. |
| + | * '''Scrubbing''' filters out any gases that are selected in the '''Filters''' section. |
| + | * '''Siphoning''' indiscriminately sucks up all gases. |
| + | * '''Range''' specifies how effective the scrubbers are - on '''Normal''' range they only work on their own tile, while on '''Expanded''' they work in a 3x3 range. |
| + | |
| + | |
| + | '''Operating Mode''': you can select a preset mode for the scrubbers and vents in the area: |
| + | * '''''Filtering''''': Default mode, scrubbers are set to filter CO2 on their tile, vents are set to keep the area at normal pressure (101.3 kPa). |
| + | * '''''Contaminated''''': Scrubbers now filter all harmful gases in Expanded mode, vents are set to normal pressure |
| + | * '''''Draught''''': Scrubbers are set to Siphon and vents are set to twice the normal pressure. |
| + | * '''''Refill''''': Scrubbers are ON and vents are set to three times the normal pressure. |
| + | * '''''Cycle''''': Panic siphons all air, then switches to Filtering mode. |
| + | * '''''Siphon''''': Scrubbers are set to siphon, vents are OFF. |
| + | * '''''Panic Siphon''''': Scrubbers are set to siphon (Expanded), vents are OFF. |
| + | * '''''Flood''''': Emag/malfunctioning AI only. Disables scrubbers, sets vents to max output and disables their pressure checks. |
| + | * '''''Off''''': Both scrubbers and vents are OFF. |
| + | |
| | | |
− | '''Activate Panic Syphons''': They turn all vents off and set all scrubbers to syphon. You *can* do better than that, but most of the methods involve setting vents to suck, and if you need a panic syphon, then sucking contaminated air into Distro kinda sucks. | + | '''Alarm Threshold''': Lets you change the minimum and maximum settings for pressure and temperature to automatically trigger the alarm. |
| }} | | }} |
| | | |